Technology:
This is the email received from the S.M.A.R.T. Long Self-test option in FreeNAS installation and is the report on a disk with errors.
Subject: SMART error (EmailTest) detected on host: p2nas.local
This email was generated by the smartd daemon running on:
host name: p2nas.local
DNS domain: [Unknown]
NIS domain:
The following warning/error was logged by the smartd daemon:
TEST EMAIL from smartd for device: /dev/ad8
For details see host's SYSLOG (default: /var/log/messages). smartctl version 5.38 [i386-portbld-freebsd7.2] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint T166 series
Device Model: SAMSUNG HD501LJ
Serial Number: S0MUJ1EPA13945
Firmware Version: CR100-11
User Capacity: 500,106,780,160 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 3b
Local Time is: Thu Feb 11 06:35:32 2010 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (9144) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 156) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 1
3 Spin_Up_Time 0x0007 100 100 015 Pre-fail Always - 7232
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 782
5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0
8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 656
10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0012 253 253 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 628
13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 2435175
187 Reported_Uncorrect 0x0032 077 077 000 Old_age Always - 24
188 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 7
190 Airflow_Temperature_Cel 0x0022 062 056 000 Old_age Always - 38
194 Temperature_Celsius 0x0022 124 106 000 Old_age Always - 38
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 2435175
196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1
198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x000a 253 100 000 Old_age Always - 1
202 TA_Increase_Count 0x0032 253 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 24 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 24 occurred at disk power-on lifetime: 655 hours (27 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 75 22 40 Error: UNC at LBA = 0x00227500 = 2258176
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 00 75 22 40 00 15:30:43.438 READ DMA
Error 23 occurred at disk power-on lifetime: 655 hours (27 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 75 22 40 Error: UNC at LBA = 0x00227500 = 2258176
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 00 75 22 40 00 15:30:40.500 READ DMA
Error 22 occurred at disk power-on lifetime: 655 hours (27 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 75 22 40 Error: UNC at LBA = 0x00227500 = 2258176
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 00 75 22 40 00 15:30:37.563 READ DMA
Error 21 occurred at disk power-on lifetime: 655 hours (27 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 75 22 40 Error: UNC at LBA = 0x00227500 = 2258176
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 00 75 22 40 00 15:30:34.625 READ DMA
Error 20 occurred at disk power-on lifetime: 655 hours (27 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 75 22 40 Error: UNC at LBA = 0x00227500 = 2258176
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 00 75 22 40 00 15:30:31.688 READ DMA
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1
SMART Selective self-test log data structure revision number 0
Warning: ATA Specification requires selective self-test log data structure revision number = 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.





- Facebook Like